Products ---- Industrial paint Series
UV2100 plastic & rubber UV gloss oil
Description: UV2100 is a cost-effective UV products. The product uses the latest formation mechanism and special processing technology, it has a protruding surface leveling effect and surface dirt oil capacity, and to maintain a high yield. Recommended to use with the company supporting the 6188 series UV primer. Products applicable to ABS, PC, ABS + PC plastic substrates, high film hardness, good adhesion, leveling excellent, water and salt spray resistance excellent, high hardness and wear resistance, in line with EU RoHS2002/95/EC instruction
Scope: apply to all types of high-end electronic products cabinet UV coating, such as mobile phones, CD players, MP3, MP4, notebook computers, digital cameras, etc.
Product composition: a photocurable polyurethane resin, a photoinitiator, a reactive diluent
Finished Size:
Appearance (visual): clear, colorless or slightly yellow transparent liquid
Solids: 70-75%
Viscosity (2# Iwata cup & 25ºC): 26.5-30s
Spraying viscosity (2# Iwata cup & 25ºC): 8.5-9.0s
Technical Parameters:
Leveling (visual) | excellent |
Adhesion (100 grid, 3M tape) | 100/100 |
Gloss (60 ° angle) | 110 |
Hardness (Mitsubishi Pencil) | H |
RCA wear (175g force, 13μm thick, views) | <500 |
Salt spray test (35ºC, 87% PH=6.5-7.2 48h) | Pass |
Construction Technology: material - cleaning → spraying 6188 series UV primer - thermal curing (60ºC×30min) → UV 2100UV gloss oil -UV curing → test and packaging.
Coating way: manual spray or spraying automatic production line
Thinner: V701
Dilution ratio: UV2100: V701=1: 0.6-0.8
Precautions:
1, first Stir well before use
2, after opening the oil seal, attention away from ultraviolet radiation
3, the substrate surface stains should be cleaned before spraying to ensure adhesion coefficient
4, with a 300 mesh filter and then spraying
5, compressed air and a variety of instruments to be dry, clean
6, dust-free environment before spraying into the UV curing machine
Packing: 20KG/barrel
Security Code:
1, flammables, do not close the fire;
2, the construction, storage areas must be kept coating and painting workplace air circulation;
3, other usage guidelines, refer to "Material Safety Data Sheet."