Products ---- Industrial paint Series
UV6200vacuum plating top-coat
Description: UV6200 vacuum plating top-coat layer is very good adhesion of the coating to provide a very excellent protective effect of the coating layer. While the increase in top-coat made of colorful hues surface effect, paint film is smooth, moderate hardness and flexibility, chemical resistance, excellent. Compliance with EU RoHS2002/95/EC directive.
Scope: apply to cosmetics and handicrafts vacuum plating surface coating
Product composition: a photocurable polyurethane resin, a photoinitiator, a reactive diluent
Finished Size:
Appearance (visual): colorless to pale yellow transparent liquid
UV Active ingredient: 45-50%
Viscosity (2# Iwata cup & 25ºC): 8.5-8.8s
Technical Parameters:
Surface effects (visual) | excellent |
Adhesion test (5 times per cell 3M tape) | 5B |
Hardness (Mitsubishi Pencil) | H |
RCA wear (175g force 13μm film thickness) | ≥200 times |
Bending experiments (positive 90 ° bends 3 times) | No cracks |
Salt spray test (35ºC80% PH=6.5-7.248h) | Pass |
Acid test (1000g force 40-60 times/min300 times.) | Pass |
Constant temperature (85ºC±3ºCRH90-95% 48h) | Pass |
Cosmetic resistance test (60±2ºCRH90±2% 24h) | Pass |
Alcohol-resistant test (1000g force) | ≥210 times |
Construction Technology: material - Clean → vacuum plating primer UV3300-UV curing (600-800mj/cm 2) → PVD coating - → vacuum plating top-coat UV6200-UV curing (800-1000mj/cm 2) → testing and packaging.
Coating way: manual spray or spraying automatic production line
Thinner: spray directly
Precautions:
1, the amount of color finishing in the top-coat, must be <3%
2, please Stir well before use
3, after opening the oil seal, attention away from ultraviolet radiation
4, the substrate surface stains should be cleaned before spraying to ensure adhesion coefficient
5, with a 300 mesh filter and then spraying
6, compressed air and a variety of instruments should be dry, clean
7, a dust free environment before spraying into the UV curing machine
Packing: 18KG/barrel
Security Code:
1, flammables, do not close the fire;
2, the construction, the coating must be maintained storage sites and coating properties of air circulation;
3, other usage guidelines, refer to "Material Safety Data Sheet."